CONSIDERATIONS ON THE MEASURED AND CALCULATED POTENTIAL EVAPOTRANSPIRATION IN THE CITY OF GOIÂNIA AND SURROUNDINGS

Authors

  • Olivar José da Silva M. Lobato UFG
  • Engler José Vidigal Lobato UFG

DOI:

https://doi.org/10.5216/pat.v9i1.2364

Abstract

In this paper the author compared the potential evapotranspiration calculated by methods of THORNTHWAITE, CAMARGO, HOLDRIDGE, BLANEY-CRIDDLE, GRASSI-CHRISTIANSEN and GARCIA-LOPEZ, with the direct measurement from the evapotranspirometer of THORNTHWAITE & MATHER, in Goiânia (Goiás-Brazil) and surrounding counties. All the methods studied presented a significant correlation when compared with the measured data. The correlation coefficients were: THORNTHWAITE, r = 0.96, CAMARGO, r = 0.94, HOLDRIDGE, r = 0.94, BLANEY-CRIDDLE, r = 0.91, GRASSI-CHRISTIANSEN, r = 0.70, GARCIA-LOPEZ, r = 0.62.

Downloads

Download data is not yet available.

Published

2007-11-12

Issue

Section

Research Article

How to Cite

LOBATO, O. J. DA S. M.; LOBATO, E. J. V. CONSIDERATIONS ON THE MEASURED AND CALCULATED POTENTIAL EVAPOTRANSPIRATION IN THE CITY OF GOIÂNIA AND SURROUNDINGS. Pesquisa Agropecuária Tropical [Agricultural Research in the Tropics], v. 9, n. 1, p. 50–73, 12 Nov.2007.